GD6900 Te Kaha me te Whakamatau Factor Dissipation
Ka ine te GD6900 i te kaha me te tauwehe mate dielectric (tgδ) o nga taputapu hiko ngaohiko teitei.He hanganga whakauru, he piriti whakamatautau mate dielectric i hangaia, he rereke te rereke o te hiko ka taea te whakarite, te whakanui i te huringa me te SF6 paerewa paerewa.
Ko te puna ngaohiko teitei ka hangaia e te kaitahuri o roto o te taputapu, ka whakamahia hei whakamatautau i nga mea whakamatautau i muri i te whakanui i te huringa.Mena ka taapirihia he kapu whakamaarama me te taputapu whakamaarama, ka taea te whakamatautau i te mate hiko o te hinu whakaahuru.
●Pa ki te whakaaturanga mata LCD.
●Te inenga aatete whakamaarama: Ko te waahanga whakamatautau aatete whakamaarama i roto, ka taea te whakahaere i te whakamaaramatanga o te whakamaarama (IR), te owehenga whakauru (DAR), te tohu tohu polarization (PI).
●Maramataka maramara me te rokiroki nui ki roto.Tiakina nga hua whakamatautau kia rite ki te raupapa o te waa, tirohia te rekoata hitori me te tuhi i te hua.
●Ko nga raraunga taputapu ka taea te kaweake ma te U kōpae.
●Te aratau whakamatautau maha, me nga momo o roto ngaohiko teitei, ngaohiko teitei o waho, te paerewa o roto, te paerewa o waho, te GST/UST, te whakaihiihi whaiaro.Ngaohiko teitei (neke atu i te 10kV) ka taea te whakamatautau mate dielectric i roto i te ahuatanga o te paerewa o waho o waho ngaohiko teitei.
●Whakamātautauhia te CVT hiri katoa (Capacitive Voltage Transformer) C1 me C2 mate dielectric me te kaha i te wa ano.Whakamātauria hoki te ōwehenga huringa CVT me te rerekētanga koki ngaohiko.
●Ko te ngaronga dielectric me te uara kaha o C0 i te pito o runga o te CVT ka taea te ine ma te whakamahi i te tikanga whakamarumaru whakamuri.
●Te tohu tohu tohu tere teitei.Ko te hurihanga me te iahiko tauira o roto ka whakamamatihia te whakahaere.Ko te ngaohiko putanga ka whakatika tonu.
●LCR inenga aunoa.Inductance, capacitance, resistance, koki e taea te ine me te whakaatu.
●Te whakamarumaru maha o nga huringa ngaohiko whakauru, te whakaputa iahiko poto, te ngaohiko nui, te nui o te waa, te pāmahana, te haumaru me te pono.I tenei wa, kei a ia te mahi o te whakamatautau whenua, kaore e whakaaetia te whakanui ngaohiko mo nga taputapu kore-papa.
●Kaore he take ki te wetewete i te arahi HV ki te ine i te mate dielectric me te kaha o te CVT.
●Ka taea te huri i te auau ki te 50Hz, 47.5Hz/52.5Hz, 45Hz/55Hz, 60Hz, 57.5Hz/62.5Hz, 55Hz/65Hz.
Te ahua mahi | -15℃~40℃ | RH<80% | ||||||
Tikanga parepare | Te hurihanga auau | |||||||
Tuku hiko | AC 220V±10%, 50/60Hz | Ka taea te whakamahi generator. | ||||||
Putanga ngaohiko teitei | AC 0.5KV~10KV (12kV te kōwhiri) | Ia 0.1kV | ||||||
Tika | 2% | |||||||
Max.nāianei | 200mA | |||||||
Te kaha | 2000VA | |||||||
Te mana whakaihiihi whaiaro | AC 0V~50V/15A | 50Hz, 60Hz auau kotahi 45HZ/55HZ 47.5HZ/52.5HZ 55HZ/65HZ 57.5HZ/62.5HZ Aunoa rua auau | ||||||
Whakatau | tg: 0.001% | Cx: 0.001pF | ||||||
Tika | ∆tgδ: ±(pānui*1.0%+0.040%) | |||||||
∆C x: ±(panui*1.0%+1.00PF) | ||||||||
Awhe ine | tgδ | Karekau he rohe | ||||||
C x | 15pF < Cx < 300nF | |||||||
10KV | Cx <60 nF | |||||||
5KV | Cx <150 nF | |||||||
1KV | Cx <300 nF | |||||||
whakamātautau CVT | Cx <300 nF | |||||||
Awhe inenga LCR | L>20H(2kV) | R>10KΩ(2kV) | ||||||
Tikanga inenga LCR | 0.1% | Whakatau | 0.01 | |||||
Awhe ōwehenga CVT | 10~10000 | |||||||
CVT tika ōwehenga | 0.1% | |||||||
Taumira ōwehenga CVT | 0.01 | |||||||
Te parenga whakaahuru | DC ngaohiko teitei | 5~10kV | Tika | ±(2%*Pānui +10V) | ||||
IR tika | 100kΩ-1000GΩ: <5% (ngaohiko whakamātautau kaua e iti iho i te 250V) 100GΩ-1000GΩ: 10% (ngaohiko whakamātautau kaua e iti iho i te 10000V) | |||||||
Ahu | Wae matua: 350(L)×270(W)×270(H) | |||||||
Pouaka apatoko: 350(L)×270(W)×160(H) | ||||||||
Te kaha mahara | 200 nga roopu, ka tautokohia te rokiroki kōpae kohiko USB. | |||||||
Taumaha | Wae matua: 22.75Kg | |||||||
Pouaka taputapu: 5.25Kg |
Kaiwhakamatau | 1 huinga |
Puhi apatoko | 1 wahi |
HV mata whero whakamātautau 8m | 1 wahi |
LV pango te mata whakamatautau 8m | 1 wahi |
Te taura hiko 1.8m | 1 wahi |
CVT Tuhono mata 5m | 1 wahi |
Mataara whenua 2m | 1 wahi |
Taa pepa | 2 roi |
10A whakakorikori | 3 mongamonga |
Aratohu Kaiwhakamahi | 1 kape |
Pūrongo Whakamātau wheketere | 1 kape |
Ko nga taputapu whiriwhiri | |
Pūtau whakamātautau hinu | 1 pc |
Kaiwhakahaere whakawera | 1 pc |
Ma te pūtau whakamatautau hinu me te kaiwhakahaere whakawera, ka taea e te kaiwhakamahi te whakamatautau tan delta o te wai dielectric penei i te hinu whakawhiti.
Kaiwhakahaere whakawera
Waka hinu