GDCR-3200C Rawhi Taurua Multifunctional Earth Resistance Tester
GDCR3200C Rawhi Taurua Multifunctional Earth Resistance Tester he mea hangaia me te hanga mo te ine i runga i te waahi o te parenga papa, te parenga o te oneone, te ngaohiko o te whenua, te naianei o te rerenga o te raina, te naianei AC me te aukati DC.Ka whakamahia e te taputapu te hangarau tukatuka mamati matatau, me te tikanga 2-waea, te tikanga 3-waea, te tikanga 4-waea, te tikanga whiriwhiri, te tikanga rawhi rua me etahi atu tikanga ine;Kawemai i te hangarau FFT (Fast Fourier Transform), te hangarau AFC (Automatic Frequency Control), me te kaha ki te aukati i te aukati me te urutau o te taiao, te rite tonu o te whakamatautau tuarua, te whakarite i te tino tika, te pumau teitei me te tino pono mo te inenga roa.Ko te taputapu i whakamahia hoahoa rawhi nui o naianei, ka taea ki te whakatutuki i nga momo whakaritenga whakamatautau katoa, ka taea te ine i te uara aukati papa o te rahi o te whenua ki raro te mata, ngawari ki te ine i te uara aukati o te waahi kotahi me te papaa maata me nga momo hanganga papa whenua katoa, karekau he take ki te momotu i tetahi pou whenua hono whakarara i te ine i te punaha papa whenua whakarara, ka tino pai ake te pai o te ine, na te mea he otinga tino pai te whakamatautau mahi whenua.
GDCR3200C Rawhi Taurua Multifunctional Earth Resistance Tester he mea tito ki te miihini manaaki, te rawhi o naianei(rawhi takirua), nga waea whakamatautau, te rakau awhina, te rorohiko raraunga me nga waea korero me etahi atu.Ko te whakaaturanga LCD nui o te miihini manaaki me te rama maama me te tohu kauwhata pae e kitea ana.Ko te kaiwhakamatau he mahi rokiroki, he mahi karaka, ka penapena aunoa i nga roopu 2000 o nga hua whakamatautau kei roto te ra me te wa.Ko te kaiwhakamaatau me te mahi whakawhitiwhiti Nihokikorangi e tautoko ana i te punaha Android.I muri i te whakaurunga o APP, ka taea te whakamatautau, te panui ranei i nga rekoata whakamatautau i roto i te tauranga pūkoro, ka mau mai he wheako hou.Ka whakauruhia e te kaiwhakamaatau te atanga USB, ka taea te tuku i nga raraunga rongoa ki te PC ma te atanga USB.Ka taea e te rorohiko whakawhitiwhiti te mohio ki nga mahi o te panui, te korero, te penapena, te ripoata me te ta o nga raraunga rekoata o mua.Ka whakamahia nuitia i roto i te mana, te waea, te meteorology, te hinu hinu, te hanga, te tiaki uira me nga taputapu hiko ahumahi.
●Hoahoa ahurei o te rama tohu jack, tohu tika o te tuunga jack, karo i te hapa mahi.
●Ko te kowhiri kowhiringa mahi a nga nihowhiti, he maha nga tikanga whakamatautau e whakaatuhia ana, kia ngawari te mahi me te tere.
●Ko te kaiwhakaatu he mahi whakawhitiwhiti Nihokikorangi me te tautoko i te punaha Android.Ka taea e nga kaiwhakamahi te whakamahi i te tauranga pūkoro ki te whakamatautau i te mahi, ki te panui ranei i nga hua whakamatautau kei roto i te ra me te wa tino watea.
●Ko te pouaka taputapu ka tango i te pouaka whakamarumaru parewai, he kaha, he haumaru, he roa mo te aukati i te tukinga, te aukati-hinga me te parewai (te karaehe tiaki IP65), he pai rawa mo te whakamahi i nga waahi hanga o waho.
●Ko te mita he mea nui ki te kohinga pākahiko lithium rechargeable.A me te atanga USB ki te tuku i nga mahi raraunga.
Tikanga taketake & tikanga Mahi
Te Rahi Whakaawe | Tikanga Turanga | Nga Tikanga Mahi | Korero |
Ambient Temp | 23℃±1℃ | -10℃-40℃ | ---- |
Haumākū Ambient | 40%-60% | <80% | ---- |
Ngaohiko Mahi | 7.8V±0.1V | DC 7.8V±0.6V | ---- |
Ātete Whenua Āwhina | <100Ω | <5kΩ | |
Ngaohiko pokanoa | Me karo | <20V | |
Porearea o naianei | Me karo | <2A | |
Tawhiti Hiko i te ine i te R | a>5d | a>5d | |
Tawhiti Hiko i te ine i te ρ | a>20h | a>20h |
Whakatakotoranga whānui
Mahi | Te ine i te parenga whenua, te parenga o te oneone;Te ātete DC, te ngaohiko whenua, te naianei tau, te naianei turuturu | |
Tuku Hiko | DC 7.4V 2600mAh pākahiko lithium rechargeable, ki tonu i te 8.4V | |
Whakamuri | Ka taea te whakahaere i te rama mata, e tika ana mo nga waahi pouri | |
Tikanga Ine | Atete DC | Tikanga 2-waea te aukati DC |
Tikanga 4-waea te aukati DC | ||
Te ātete ki te whenua | Tikanga 2-waea parenga whenua | |
Tikanga 3-waea parenga whenua | ||
Tikanga 4-waea parenga whenua | ||
Atete whenua rawhi kotahi tikanga 3-waea (tikanga whiriwhiri) | ||
Atete whenua rawhi kotahi tikanga 4-waea (tikanga whiriwhiri) | ||
Ātete whenua doubte tikanga rawhi | ||
Te parenga oneone(Wenner tikanga) | ||
Te au o te whenua | Inenga rawhi o naianei | |
Ngaohiko whenua | Whakatikatika toharite | |
Ngaru Ngaohiko Whakamatau | Ngaru Hine | |
Auautanga Whakamatau | 128Hz/111Hz/105Hz/94Hz(AFC) | |
Whakamātautau iahiko poto o nāianei | AC 250mA teitei | |
Tuwhera-iahiko Whakamatau Naianei | AC 40V teitei | |
Awhe Tawhiti Hiko | 1m-100m | |
Aratau Whakaatu | Whakaaturanga LCD nui 4-mamati, me te whakamarama mata | |
Tohu Ine | I roto i te inenga, tohu kohiko LED, whakaaturanga tataunga LCD | |
Ahu anga LCD | 128mm×75mm | |
rohe whakaatu LCD | 124mm×67mm | |
Ahu taputapu | 280mm(L) X 260mm(W) X 160mm(H) | |
CT Rahi | 223mm X 120mm X 39mm | |
Waea Whakamatau | E 4 nga waea: mo ia 20m whero, 20m pango, 10m kowhai, me te 10m matomato | |
Waea Whakamatau Maamaa | 2 waea: mo ia mo te 1.6m whero me te 1.6m pango | |
Tautoko Whakapapa Papa | 4PCS: Φ10mm X150mm | |
Rawhi o nāianei | 2PCS :1 puru-pango mono me 1 whero-pango mono | |
Clamp Caliber | Φ70mm | |
Rawhi Waea Arataki | 2m | |
Reiti Ine | AC nāianei: āhua 2 wa/hekona | |
Ngaohiko Whenua: tata ki te 2 wa/hekona | ||
Te ātete ki te whenua: tata ki te 7 hēkona/wā | ||
Wā ine | Neke atu i te 5000 nga wa (Whakamatau iahiko-poto, me 30 hēkona te wa mokowhiti) | |
Ngaohiko Raina | Ine i raro AC 600V | |
Atanga Whakawhitiwhiti | Ko te kōwae Nihokikorangi, te atanga USB, te raraunga rokiroki ka taea te tukuake ki te rorohiko, ka tiakina, ka taia ranei. | |
Waea Whakawhitiwhiti | Waea korero USB x1pcs, me te 1.5m te roa | |
Pupuri Raraunga | Te mahi pupuri raraunga: "HOLD" whakaatu tohu | |
Rokiroki Raraunga | 2000 nga roopu, "MEM" tohu rokiroki, "FULL" tohu whakaatu kohiko kua ki tonu te rokiroki | |
Uru Raraunga | Taumahi panui Raraunga: "READ" whakaatu tohu | |
Whakaatu Puawai | Whakanuia te awhe ine inenga mahi: whakaatu tohu "OL". | |
Tohu o naianei iti o te rawhi o naianei | Ko te ine me te tikanga whiriwhiri, te rawhi rua ranei, ko te tohu o naianei kua riro mai i te CT2 he iti iho i te 0.5mA, ka whakaatu" ", me tirohia te ahunga awhi o te rawhi CT2 o naianei. | |
Whakamātautau pokanoa | Te tautuhi aunoa i nga tohu pokanoa, tohu tohu "NOISE" ina teitei ake te ngaohiko pokanoa i te 5V | |
Whakamātautau Tautoko Papa | Me te mahi whakamatautau parenga papaa awhina, 0.00KΩ-30kΩ(100R+rC<50kΩ, 100R+rP<50kΩ) | |
Mahi Whakaoho | Ka nui ake te uara ine i te uara tautuhinga whakaoho, ka puta te tangi whakaoho "Toot-toot-toot". | |
Ngaohiko Pūhiko | Ahakoa ka heke te ngaohiko pākahiko ki te 7.2V±0.1V, ka whakaatu te tohu iti ngaohiko pākahiko, me te whakamahara ki te whakakapi i te pākahiko. | |
Whakaweto Aunoa | Katia aunoatia i muri i te 15 meneti o te hiko | |
Mahi Naianei | Maama Whakamuri: 25mA Max(ko te kohi hiko rama rama anake) | |
Tatari: 25mA Max(Ka weto te rama tuara i muri i te hiko hiko) | ||
Inenga: 150mA Max(Kati te rama tuara) | ||
Taumaha | Whakamatau: 2290g | |
Rawhi o nāianei:1100g(2pcs) | ||
Te taumaha katoa: 6800g(me nga taputapu katoa) | ||
Te Pamahana Mahi me te Haumarutanga | -10 ℃-40 ℃, i raro i te 80% rh | |
Te pāmahana rokiroki me te haumākū | -20 ℃-60 ℃, i raro i te 70% rh | |
Taumata Tiaki | IP65(kati te take) | |
Parenga taumaha | Ine te ātete whenua: i waenga i ia atanga o C(H)-E,P(S)-ES, AC 280V/3 hēkona | |
Ātete Wehenga | Neke atu i te 20MΩ(i waenga iahiko me te anga o waho he 500V) | |
Ngaohiko Tuturu | AC 3700V/rms.(I waenga iahiko me te anga o waho) | |
Ngā Āhuatanga Hiko | IEC61326(EMC) | |
Momo Tiaki | IEC61010-1(CAT Ⅲ 300V,CAT IV 150V,Parahanga 2); IEC61010-031; IEC61557-1(Atete whenua); IEC61557-5(Te parenga oneone); JJG 366-2004(Mita parenga whenua) JJG 1054-2009(Rawhi i te mita atete papa) |