GDPQ-5000 Kaitirotiro Kounga Mana
Ko te GDPQ-5000 Power Quality Analyzer he taputapu whakamatautau matawhānui i whakawhanakehia e ta maatau kamupene me te mea i hangaia mo te whakamatautau mara mo nga waahanga e toru, he maha nga mahi me te mohio, te mahi miihini-tangata.He ngawari ki te whakamahi, he whakaaturanga mata LCD nui, he taumira teitei, he atanga i roto i te reo Hainamana me te reo Ingarihi, te hanganga anga ohorere me etahi atu.Ka taea i te wa kotahi te ine i te naianei 4-hongere (e toru nga wahanga ABC me te naianei waea kupapa), ngaohiko 4-waahanga (te ngaohiko ABC e toru-waahanga me te ngaohiko raina kupapa ki te whenua), te uara teitei o te ngaohiko o naianei, te uara teitei / iti mo te waa. , toru-waahanga tauwehenga tauwehenga, wa poto ngaohiko korakora, huringa K tauwehe, mana hohe, mana tauhohenga, mana kitea, tauwehe mana me te tauwehe mana displacement, mana hohe, mana hohenga, mana kitea, te katoa o te whakakorikori me te haurite, aha atu;Whakaatuhia te wa-tūturu ngarurangi, te tauwehenga orite nga mahere pae o te ngaohiko o naianei;Kapohia te huringa inamata o te ngaohiko o naianei, te aro turuki i te tiimata o te naianei, te aro turuki i nga tawhā hiko me te whakaputa i te raarangi whakaoho, te whakaputa i te tūtohi ia mo te wa roa te rekoata i nga raraunga whakamatautau.
GDPQ-5000 Power kounga kaitātari tango DSP + ARM hangahanga pūtukatuka rua, DSP te whakamahi mo te kohinga raraunga me te tukatuka o te hātepe, te ARM te whakamahi mo te kawa kōrero me te tukatuka atanga tangata-miihini;Ko te whiwhi tohu tairitenga e 2 nga waahanga AD7655 o te kamupene ADI.Ko te whakataunga mo AD7655 he 16 bit, he 4 hongere tauira tukutahi.Ko te reiti tauira teitei ka eke ki te 1 MSPS, hei whakarite i te tika o te hongere me te pono o nga korero, kia kore ai e ngaro nga huringa o te matiti, ka taea e koe te tino tika ki te kite i te pikinga o te ngaru tere me te heke nui, me te ngaru i te wa poto. ;Ko te auau mahi DSP kei runga ake i te 200 MHZ, kia taea ai e koe te aro turuki i te matiti hiko me te whakatikatika i te auau tauira kia mohio ai te tukutahitanga o te auau hiko me te auau tauira;Ma te whakamahi i te 5.6-inihi whakaatu mata tae LCD, he taumira o 640 ira x 480 ira, me te rereke rereke o te tae whakaatu i waenga i nga tawhā o te waahanga, te ngaru, te hoahoa vector, te tauwehenga hauhautanga, ka taea e te kaiwhakamahi te pai ake me te mohio ki te ahua o te ahua. o tawhā mātiti hiko.Ka taea e te mahara kohiko te pupuri i te 60 roopu whakaahua i te wa kotahi, 150 nga roopu hopu ngaohiko / ahua ngaru o naianei, me nga roopu 12800 o te raarangi whakaoho.Ka taea e te tiimata te tauira rapunga o naianei te hopu tonu i te ahua ngaru o naianei mo te 100 s.Ko te kaari mahara 2G i hangaia hei penapena i te rekoata o te ia, te tuhi tukutahi 20 tawhā (ka taea te whiriwhiri kia rite ki te hiahia) kohikohi raraunga mo te kotahi i ia rima hēkona, ka taea te penapena i nga rekoata pihi au mo te 300 ra.
Kei te kiia hoki ko te Kaitirotiro Kounga Hiko Maamaa E toru nga waahanga, te Kaitirotiro Kounga Hiko Mahi-maha, he rite tonu ki nga mahi o te kaitirotiro hauhautanga, te mita volt-ampere mita,te kaiwhakaatu tawhā hiko.E pa ana ki te ahumahi hiko, petrochemical, metallurgy, reriwe, umanga maina, whare rangahau pūtaiao, tari metrological.He pai rawa mo te tātaritanga matawhānui me te tātaritanga i runga i te ngaohiko katoa, o naianei, te mana, te mana, te pai, te waahanga hiko.
2.1.Mahi ine
●Whakaatu wa-tūturu puka ngaru (4 ngaohiko ngaohiko/4 nga hongere o naianei).
●Nga uara RMS pono o nga ngaohiko me nga ia.
●Ko nga waahanga DC o nga ngaohiko.
●Ngā uara o nāianei me te ngaohiko.
●Te iti me te haurua haurua teitei RMS o naianei me nga uara ngaohiko.
●Whakaaturanga hoahoa Phasor.
●Te inenga o ia haurite ki te ota 50.
●Ka whakaatuhia e nga tūtohi pae nga owehenga orite o naianei me te ngaohiko o ia wahanga.
●Tapeke haukoetanga distortion (THD).
●Te kaha kaha, te hohenga, te kaha kitea, ma te waahanga me te taapiri.
●Te kaha, te tauhohenga, te kaha kitea, ma te waahanga me te taapiri.
●Kaihuri K tauwehe.
●Ko nga mea hiko (PF) me nga waahanga nekehanga (DPF, COSΦ ranei).
●Ngaohiko ngaohiko mo te wa poto (PST).
●E toru nga wahanga kore taurite (naianei me te ngaohiko).
2.2.Mahi hopu puhoi
Te aro turuki i nga huringa inamata o nga tawhā ngaohiko o naianei matiti hiko, tae atu ki nga rereketanga o naianei, ngaohiko ngaohiko o naianei, te sag me te aukati poto, te ngaohiko mo te wa poto, te paahitanga o naianei me te ngaohiko o naianei korirangi inamata.Ka taea e nga taputapu te penapena 150 nga huinga ngaru whakawhiti i te wa kotahi.
2.3.Ka timata te aroturuki o naianei
Ko te aro turuki i te ngaru o te raina me te naianei whakaoho i te wa e timata ana nga taputapu hiko, ka awhina ki te hoahoa tika.Ka taea te whakaatu i te arai piki / heke RMS I roto i te tukanga whakaoho, te kopaki o te konae whakaoho, te ahua ngaru o te 4 hongere o naianei me te 4 ngaohiko ngaohiko.Te tuhi mo te 100s i muri i te keu, rokiroki te naianei / ngaohiko inamata me te ananga ngaru o ia huringa i roto i te 100s.
2.4.Te tuhi tūtohi ia me te mahi rokiroki
Whakaorangia nga tawhā whakamatautau katoa o nga mahi whakamatautau taketake (Urms, Uthd, Ucf, Uunb, Hz, Vrms, Vthd, Vcf, Vunb, PST, Arms, Athd, Acf, Aunb, KF,W, VAR, VA, PF, COSφ, TANφ), 50 ngaohiko ngaohiko, 50 ngaa o naianei.A ka hanga i te pihi au.Tuhia nga raraunga mo te wa roa kia rite ki te hiahia (kowhiringa kotahi 20 nga tawhā hei tuhi raraunga mo te wa kotahi ia rima hēkona, ka taea e koe te tuhi mo te 300 ra.).
2.5.Mahi whakaoho
Whakatakotoria nga uara rohe kia rite ki te hiahia, te aro turuki i nga uara mehemea ka nui ake, ki te overshoot ka whakaputa i te raarangi whakaoho, penei i te: ngaohiko, te naianei, te kore taurite, te tauwehenga orite, te auau, te kaha kaha, te whakakorikori katoa.Ka taea e koe te whirihora i nga momo whakaohooho rereke e 40, ka taea e ia roopu te whakarite i nga tawhā aroturuki rereke (tae atu ki te 50 harmonics, te katoa o te 123 nga tawhā rereke) me te whakawhäiti i nga uara, ka taea hoki te whakarite i te wa poto rawa atu o te overshoot.Tae atu ki te 12,800 nga whakaohooho kei roto i te raarangi.
2.6.Mahi whakaahua
Ka taea te tiaki i tetahi mata (whakaahua mata), i te wa ano ka tuhi aunoa i te waa me te aratau whakamatautau.Ka taea te whakaora i te ngaohiko me te ngaru o naianei, te tūtohi pae pai, te hoahoa phasorme etahi atu. Ka taea e ia te penapena i te 60 nga whakaahua mata.
2.7.Mahi whakawhitiwhiti
Whakawhitiwhiti korero ki te rorohiko ma te USB, Ka taea e te rorohiko Aroturuki te whakaatu i te ahua ngaru o te tātaritanga kounga hiko, te panui o te ngaru tere, te tuhi tūtohi ia, te raarangi whakaoho, nga whakaahua, me te whakaatu ki te rorohiko.
2.8.Taumahinga tautuhi
Ka taea e te kaiwhakamahi te whirihora i te wa me te ra, te whirihoranga o te rereke me te kanapa o te mata, te whakamaramatanga o nga tae o ia waahanga.
Te whiriwhiri mo te momo hononga ki te whatunga.
Te whirihora o te momo o nga pūoko o naianei me nga owehenga ngaohiko.
2.9.Tahua awhina
Ka taea e ia wahanga mahi te pehi i te taviri "awhina" kia whiwhi korero e tika ana.
3.1.Te ahuatanga turanga me te ahua mahi
cTauwehe awe | Tuemi whakamatautau | Te huru turanga | Te ahua mahi |
Te pāmahana taiao | Tawhā katoa | (23±2)°C | -10°C~ 40°C |
Te haumākū pātahi | Tawhā katoa | 40%~ 60% | <80% |
Wāhanga-ki-kūpapa ngaohiko | Tawhā katoa | (100±1%)V | 1.0V~ 1000V |
Wāhanga-ki-wāhanga ngaohiko | Tika RMS ngaohiko wahanga-ki-waahanga | (200±1%)V | 1.0V~ 2000V |
o nāianei | RMS pono o naianei | (5±1%)A | 10mA~ 10A |
auau whatunga | Tawhā katoa | 50Hz±0.1Hz | 40Hz~ 70Hz |
Huringa wahanga | Te kaha kaha me te kaha kaha | Cosφ=1 | Utu: 0.2~ 1.0 |
Te kaha tauhohenga me te kaha urupare | Haraφ=1 | Waiφ: 0.2~ 1.0 | |
Harmonic | Tawhā katoa | <0.1% | 0.0%~ 100% |
Ngaohiko kore taurite | Tawhā katoa | <10% | 0.0%~ 100% |
Ngaohiko mahi o te taputapu | Tawhā katoa | DC9.8V±0.1V | DC9.5V~ 10.5V |
mara hiko o waho, papa autō | Tawhā katoa | Me karohia | |
Te tuunga whakamatautau | Kua inehia nga tawhā whai pānga o te nāianei | I whakamatauria te waea i te pokapū o te rawhi. |
3.2.Whakatakotoranga whānui
Tuku hiko | Pukahiko lithium-ion ka taea te utu 9.6V, he utu taapiri. |
Tohu pūhiko | Ko te tohu pākahiko e whakaatu ana i te kaha putunga.Ina he iti rawa te ngaohiko, ka kati aunoa i muri i te 1 meneti. |
Kohi hiko | Ko te kai o naianei o te whakamatautau noa 490 mA, mahi tonu mo nga haora 8. |
Aratau whakaatu | Mata tae LCD, 640dots×480dots, 5.6 inihi, rohe whakaatu: 116mm×88mm. |
Te rahi o te rawhi | 008B iti koi rawhi nāianei: 7.5mm×13mm; |
Te rahinga taputapu | L×W×H: 240mm×170mm×68 mm. |
Te maha o nga hongere | 4U/4I. |
Wāhanga-ki te wahanga ngaohiko | 1.0V~2000V. |
Wāhanga-ki-kūpapa ngaohiko | 1.0V~1000V. |
o nāianei | 008B rawhi nāianei: 10mA~10.0A; |
Auautanga | 40Hz~70Hz. |
Tawhā o te hiko | W, VA, Var, PF, DPF, cosφ, tanφ. |
Tawhā pūngao | Wha, Varh, Vah. |
Harmonic | Raupapa 0~50. |
Tapeke hauhautanga distortion | Ota 0~50, ia wahanga. |
Aratau tohunga | Ae. |
Te maha o nga rekoata Whakawhiti | 150 huinga. |
Ngaohiko kopa | Ae. |
Ka timata te aratau o naianei | Ae, 100 hēkona. |
3 nga wahanga kore taurite | Ae. |
Tuhia | 300 ra(rekoata tukutahi 20 tawhā, tuhi kotahi ira ia 5 hēkona). |
Min/Max uara tuhi | Te inenga o nga uara morahi me te iti rawa mo te waa. |
Whakaoho | 40 momo momo whiringa tawhā, 12,800 nga huinga raupapa whakaoho. |
Te tihi | Ae. |
Whakaaturanga hoahoa Phasor | Aunoa. |
Te kaha o nga whakaahua | 60. |
Te reo tahua | Ingarihi |
Whakawhitiwhiti | USB. |
Whakaweto aunoa | I te wa ka timatahia he whakaoho whakaoho, he rapu ranei mo nga mea kua pahemo, he hopunga o naianei, he rekoata au kei te tatari, kei te ahu whakamua ranei, kaore te taputapu e whakaweto aunoa. |
I etahi atu aratau whakamatautau, 15 meneti kaore he patene, ka tutakina aunoa i muri i te tere 1 meneti. | |
Mahi rama tuara | Ae, he pai mo te whakamahi i te po me te waahi pouri. |
Taumaha | Kaihautū: 1.6kg (me te pākahiko). |
008B iti koi rawhi nāianei: 170g×4; | |
Te roa o te waea whakamatautau ngaohiko | 3m. |
Te roa o te waea puoro o naianei | 2m. |
Te pāmahana mahime te haumākū | -10°C~40°C;raro 80%Rh. |
Te pāmahana rokiroki me te haumākū | -10°C~60°C;i raro i te 70%Rh. |
Te aukati whakauru | Te aukati whakauru o te ngaohiko whakamatautau: 1MΩ. |
Tuturu ngaohiko | Tuturu 3700V/50Hz ngaohiko AC sinusoidal mo te 1 meneti i waenga i te waea taputapu me te anga. |
Wewete | I waenga i nga waea taputapu me te anga ≥10MΩ. |
Hanganga | Waihanga rua, me te putunga wiri-whakarewa. |
Ture haumaru | IEC 61010 1000V Cat III / 600V CAT IV, IEC61010-031, IEC61326, Tohu Parahanga: 2. |
3.3.Tikanga taputapu (haunga te pūoko onāianei)
Whakauruhia nga raraunga e whai ake nei (i runga i nga ahuatanga o te turanga me nga pukoro o naianei tino pai, he raina tika, kaore he nekehanga o te wahanga).
Inenga | Awhe | Whakaatu taumira | Ko te hapa morahi o te awhe o te tohutoro |
Auautanga | 40Hz~ 70Hz | 0.01Hz | ±(0.03)Hz |
Ngaohiko wahanga-ki-kupapa tika RMS | 1.0V~ 1000V | Min taumira 0.1V | ±(0.5%+5dgt) |
Ngaohiko wahanga-ki-waahanga RMS pono | 1.0V~ 2000V | Min taumira 0.1V | ±(0.5%+5dgt) |
DC ngaohiko | 1.0V~ 1000V | Min taumira 0.1V | ±(1.0%+5dgt) |
RMS pono o naianei | 10mA~ 10A | 1mA taumira Min | ±(0.5%+5dgt) |
Te tihi o te ngaohiko wahanga-ki-kore | 1.0V~ 1414V | Min taumira 0.1V | ±(1.0%+5dgt) |
Te tihi o te ngaohiko wahanga-ki-waahanga | 1.0V~ 2828V | Min taumira 0.1V | ±(1.0%+5dgt) |
Te tihi o naianei | 10mA~ 10A | 1mA taumira Min | ±(1.0%+5dgt) |
Tauwehe tihi | 1.00~ 3.99 | 0.01 | ±(1%+2dgt) |
4.00~ 9.99 | 0.01 | ±(5%+2dgt) | |
Mana kaha | 0.000W~ 9.999kW | Taumira Min 0.001W | ±(1%+3dgt) Cosφ≥0.8 |
±(1.5%+10dgt) 0.2≤Cosφ<0.8 | |||
Te mana tauhohenga, arataki, capacitive ranei | 0.000VAR~ 9.999kVAR | Taumira Min 0.001VAR | ±(1%+3dgt) Waiφ≥0.5 |
±(1.5%+10dgt) 0.2≤Sinφ<0.5 | |||
Te kaha kitea | 0.000VA~ 9.999kVA | Min taumira 0.001VA | ±(1%+3dgt) |
Tauwehe mana | -1.000~ 1.000 | 0.001 | ±(1.5%+3dgt) Cosφ≥0.5 |
±(1.5%+10dgt) 0.2≤Cosφ<0.5 | |||
Te kaha kaha | 0.000Wh~ 9999.9MWh | Min taumira 0.001Wh | ±(1%+3dgt) Cosφ≥0.8 |
±(1.5%+10dgt) 0.2≤Cosφ<0.8 | |||
Te pūngao tauhohenga, arataki, capacitive ranei | 0.000VARh~ 9999.9MVARh | Min taumira 0.001VARh | ±(1%+3dgt) Waiφ≥0.5 |
±(1.5%+10dgt) 0.2≤Sinφ<0.5 | |||
Te kaha o te papa | 0.000VAh~ 9999.9MVAh | Min taumira 0.001VAh | ±(1%+3dgt) |
Koki wahanga | -179°~ 180° | 1° | ±(2°) |
Tanφ (VA≥50VA) | -32.76~ 32.76 | Taumira Min 0.001 | φ:±(1°) |
Te nekehanga o te waahanga hiko (DPF) | -1.000~ 1.000 | 0.001 | φ:±(1°) |
ōwehenga Harmonic (raupapa 1 ki te 50)(Vrms>50V) | 0.0%~ 99.9% | 0.1% | ±(1%+5dgt) |
Koki Harmonic (Vrms>50V) | -179°~ 180° | 1° | ±(3°) orite o te raupapa 1 ki te 25 |
±(10°) orite o te raupapa 26 ki te 50 | |||
Haroni katoa ōwehenga (THD THD-F ranei)≤50 | 0.0%~ 99.9% | 0.1% | ±(1%+5dgt) |
Tauwehe whakakorikori (DF, THD-R ranei)≤50 | 0.0%~ 99.9% | 0.1% | ±(1%+10dgt) |
Kaihuri K tauwehe | 1.00~ 99.99 | 0.01 | ±(5%) |
3 nga wahanga kore taurite | 0.0%~ 100% | 0.1% | ±(1%) |
3.4.Pūāhua pūoko o nāianei
Momo pūoko o nāianei | RMS pono o naianei | Hapa nui o te naianei RMS pono | Hapa Max o te koki wahanga φ |
008B rawhi o naianei | 10mA~ 99mA | ±(1%+3dgt) | ±(1.5°), Arms≥20mA |
100mA~ 10.0A | ±(1%+3dgt) | ±(1°) | |
040B rawhi o naianei | 0.10A~ 0.99A | ±(1%+3dgt) | ±(1.5°) |
1.00A ~100A | ±(1%+3dgt) | ±(1°) | |
068B rawhi o naianei | 1.0A ~9.9A | ±(2%+3dgt) | ±(3°) |
10.0A ~1000A | ±(2%+3dgt) | ±(2°) | |
300Frawhi o naianei | 10A ~99A | ±(1%+3dgt) | ±(3°) |
100A~3000A | ±(1%+3dgt) | ±(2°) |
Kia mahara: me hono te rawhi me nga taputapu o naianei ki nga mea e rite ana, kaore e taea te whakauru atu.
4.1.whirihoranga paerewa
Kao. | Tohunga | Te nui |
1 | Kaihautu taputapu. | 1 |
2 | Puke taputapu. | 1 |
3 | Pūoko o nāianei. | 12 (3 momo) |
4 | Waea whakamatautau. | 5 (kowhai, matomato, whero, puru, pango) |
5 | Koaka topenga. | 5 |
6 | Te tirotiro whakamatautau. | 5 |
7 | Pūurutau hiko motuhake. | 1 |
8 | taura ra USB. | 1 |
9 | CD Pūmanawa. | 1 |
10 | Puke pākahiko Lithium. | 1(I hangaia ki te taputapu) |
11 | 2GB mahara. | 1(Ponohia te taputapu) |
12 | He pukapuka pukapuka, he kaari whakamana, he tiwhikete. | 1 |
4.2.Taumaha
Kao. | Tohunga | Taumaha |
1 | Kaihautu taputapu. | 1.6Kg (me te pākahiko). |
2 | 008B iti koi rawhi naianei. | 170g*4. |
3 | 040B huri noarawhi o naianei. | 185g*4 |
4 | 068B huri noarawhi o naianei. | 530g*4 |
5 | 300Fte naianei coil hangoreawhi(me te whakauru). | 330g*4 |
6 | Waea whakamatautau me te urutau hiko. | 900g. |