GDSF-311WPD 3-In-1 SF6 Kaitātari Hau
Ko te GDSF-311WPD (GDSF-411WPD) he taputapu pai i te wa e tika ana ki te whakamatautau i te ihirangi wai, te ma me nga hua pirau o te hau SF6.Ko te waahanga matua o te whakamatautau tohu tomairangi ko te DRYCAP® raupapa pūoko i hangaia e te kamupene Finland Vaisala.Ko te maataapono infrared SF6 hau parakore whakamatautau pūoko i hangaia e te Kamupene Sensor Pakeha ka whakamahia hei whakamatautau i te ma o te hau SF6.Ko te pūoko hiko i hangaia e te Kamupene Mombabo i Switzerland ka whakamahia hei huānga mohio mo te whakamatautau i nga hua whakangao hau SF6.Ma nga maramara taputapu ngaio me nga raupaparorohiko pai rawa atu o STMicroelectronics, kua whakaputahia e matou he reanga hou o te kaitirotiro hau 3-i-1.
SF6Te haumākū
●Tikanga ine: Tikanga ine parenga me te Puakaha
●Awhe ine: ira tomairangi -80℃--+20℃(tautoko ppmv)
●Tika: ±1℃
(i te mea kei raro iho te haupapa o te haupapa i te 0 ℃, ko te putanga o te pūoko ko te haupapa)
●Wā Whakautu: 63% [90%]
+20→-20℃ Td 5s[45s]
-20→-60℃ Td 10s[240s]
●Whakatau: 0.01℃
●Te Tukurua: ± 0.5 ℃
●Waeine whakaatu: ℃, ppm, ℃P20(kua tahuri ki te 20℃)
●Te rere o te hau: 400-600ml / min
●Whakaatu Rere: 0-1000mL mita rere mamati
●Te pehanga hau tauira: ≤1MPa
SF6Maamaa
●Tikanga ine: Tikanga Ine Pokarekarenga (Nga pūoko raupapa NDIR)
●Awhe ine: 0 ~ 100% SF6
●Wā whakautu: [90%] 60s
●Tika: ± 0.5%FS
●Te Tukurua: ± 0.5%
●Taumira: 0.01%
●Waeine whakaatu: %
SF6Hua Whakapara
●Tikanga ine: Tikanga Ine Maama Hiko (Pukoro raupapa Hiko)
●Awhe ine: H2S: 0 ~ 200ppmv
SO2: 0 ~ 200ppmv
CO: 0 ~ 500ppmv
HF: 0 ~ 50ppmv
●Tika: H2S: 10ppmv ±3%
SO2: 10ppmv ±3%
CO: 50ppmv ±4%
HF: 10ppmv ±3%
●Te Tukurua: H2S: 10ppmv ±2%
SO2: 10ppmv ±2%
CO: 50ppmv ±2%
HF: 10ppmv ±2%
●Whakatau: 0.01ppmv
●Waeine whakaatu: ppmv
●Te tuku hiko: 220VAC ± 10%, 50Hz, AC / DC te whakamahi, te tiaki i runga i te utu, ko te mahi tonu kaore i raro iho i te 8hours.
●Whakamahia te pāmahana taiao: -20--+60 ℃
●Te haumākū o te taiao: 90%RH
●Te awe ine uara: Kaore he paanga o te pehanga me te rere
●Rahi: 395*295*155mm
●Taumaha: āhua 2kg.
GDSF-411WPD SF6Hua Whakapara
●Tika: H2S: <10ppmv ±0.3ppmv;>10ppmv ±3%
SO2: <10ppmv ±0.3PPmv;>10ppmv ±3%
●Te Tukurua: H2S: <10ppmv ± 0.2ppmv;>10ppmv ±2%
SO2: <10ppmv ±0.2PPmv;>10ppmv ±2%
●Te hangarua me te whakakī mahi: recycling chamber 2L,wā hangarua ≤ 5min
Ma te mahi whakamaroke hau
●Rahi: 395*295*315mm
●Taumaha: āhua 5kg.
Kaiwhakamātau Matua | 1 wahi |
Whāurutau | 1 whakatakotoria |
Teflon paipa (kei roto i te rerenga whakatikatika rere me te hono tere) | 1 whakatakotoria |
paipa hiku | 1 whakatakotoria |
Nga waahanga e manawapa ana | 1 whakatakotoria |
Kaitohu | 1 wahi |
Kaiwhakamahi's Aratohu | 1 wahi |
Pūrongo Whakamātautau | 1 wahi |