Transformer Oil Gas Chromatography Pūnaha Aroturuki Online
Ko te GDDJ-DGA Transformer Oil Gas Analyzer he taputapu aroturuki ipurangi mo te hau rewa i roto i te hinu whakawhiti i runga i te hangarau chromatography hau.Ka whakatauhia te he, tuku matohi kia rite ki te uara tatūkē ma te punaha tohu tohunga.
Ka whakamahi te taputapu i te hangarau whakatauira mana toha, he mahi tātari-whaiaro me nga mahi whakaora-whaiaro.Ko ia waahanga mahi he ngoikore te hono, he mahi motuhake, he tango i te hanganga whatanga, he ngawari ki te tiaki miihini.
●Te tiaki-kore, kaore he take ki te whakakapi i te puoto hau.
●Te kimi i runga i te ipurangi te kukū me te tere tipu o H2, CO, CO2, CH4, C2H4, C2H2, C2H6.
●Ko te hoahoa modular me te hanganga kiato, he ngawari ki te tiaki, me te whakawhanui nui, ka ngawari te whakauru ki etahi atu taputapu aroturuki.
●Ko te aratau tauira hurihanga horoi ine, hei whakaata i te ahua o te hau rewa i roto i te hinu whakawhiti.
●Ko te hangarau korehau whakamomori, kaore e hiahiatia he papu maru me te whakapai ake i te pono me te pumau o te punaha.
●Ko te tīwae chromatographic matatini motuhake, hei whakapai ake i te tohu wehenga o te hanganga hau.
●Ko te kaitirotiro raina motuhake, he pono me te pono nga raraunga aroturuki, he tino tata nga hua whakamatautau ki nga raraunga taiwhanga.
●Ko te waeine motuhake i roto i te tahuhu hei whakahaere i te mahana me te makuku, hei tango i te awe o te rohe me te kaupeka.
●Ma te tino tika o te hopu raraunga, ka tangohia e ia te △-ε 24-mati ADC me te tātari mamati.Ka whakamahia te whakatikatika aunoa hei kohi i te spectrogram.
●Me nga momo whakaaturanga raraunga me nga momo patai, ripoata me te kauwhata ia.Ka taea te penapena nga raraunga o mua ki te 10 tau.
●He kaha te urutau o te taiao, te tono angitu i roto i te makariri, te pāmahana teitei, te haumākū tiketike, te waahi teitei.
●He kaha ki te aukati i te aukati, ka taea e te hototahi electromagnetic te whakatutuki i te paerewa e tika ana.
●Ma nga taumata e rua o te mahi whakaoho, ka taea te whakawhiti i te tohu whakaoho.
●Ko te huringa tātari tere, ko te huringa aroturuki iti ko te 40 meneti, ka taea e nga kaiwhakamahi te whakarite.
●Whakaotia hangarau hoki hinu, i roto i te tukanga degassing, te tauira hinu e kore e whakapā te hau kawe chromatogram, te whakamahi o te tikanga o te whakahaere, ki te whakarite kia te tinana transformer hoki o te tauira hinu tino tutuki nga whakaritenga.
●Kua whakapakarihia te punaha tātaritanga, ka puta nga hua ma te whakapai ake i nga tikanga owehenga e toru, te tikanga tapatoru a Rawiri me te tikanga hoahoa mataono.
●Me nga momo tikanga whakawhitiwhiti korero hei whakawhiti raraunga, RS485, IEC61850, GPRS whakawhiti ahokore me te karere poto ka tono ki te whakawhiti raraunga.
●Tautokohia te hononga Ethernet/optical, te whakawhiti raraunga, te mana taputapu me te tautuhinga tawhā me te tino whakarorohiko me te mana mamao.
●Kei te waatea te whakatikatika miihini hinu / hau me nga mahi horoi aunoa.
Te pāmahana taiao | -40 ℃~+70 ℃ | ||
Te haumākū taiao | Te haumākū pātata 5-95%(karekau he tōhau) | ||
Te Peketanga o te Kohauhau | 80kPa-110kPa | ||
Tuku hiko | AC 220V±10%, 50Hz | ||
Nga waahanga aroturuki | H2, CO, CO2, CH4, C2H4, C2H2, C2H6, H2O, tere tipu me te kukū | ||
Te tātari me te mahi tātari | Te tātari me te tātari raraunga aroturuki mā te tikanga ōwehenga toru, tikanga tapatoru a Rawiri me te tikanga hoahoa mataono.Ka taea te tuku i te spectrogram taketake. | ||
Min.Huringa rapunga | 40-60mins, tautuhi-kaiwhakamahi, taunoa e wha nga wa ia ra. | ||
Aratau tauira | Te whakatauira paihikara, hei whakaata i nga ahuatanga o te hau o roto. | ||
Te aratau wehewehe o te hinu me te hau | Ko te aratau whakaheke korehau, te whakaheke mo te toru nga wa tonu. | ||
Te roanga o te rokiroki raraunga | ≥ 10 tau | ||
Te rahinga hau kawe | Ko te hau kaikawe i mahia e ia ake, kare i haukotia i te tau katoa.Kaore he take ki te whakakapi i te puoto hau. | ||
Aroturuki hau | Awhe ine | Min.rapunga | Hapa |
H2 | 2- 2000 ppm | 1 ppm | ±10% |
CO | 5- 20000 ppm | 5 ppm | ±10% |
CH4 | 0.2- 2000 ppm | 0.2 ppm | ±10% |
C2H4 | 0.2- 2000 ppm | 0.2 ppm | ±10% |
C2H6 | 0.2- 2000 ppm | 0.2 ppm | ±10% |
C2H2 | 0.2- 2000 ppm | 0.2 ppm | ±10% |
CO2 | 25- 20000 ppm | 25 ppm | ±10% |
H2O | 1 - 800 ppm | ||
Te pāmahana hinu | -40℃~200℃ | ||
Te rahinga hau katoa | 0.2-15% | ||
Te waiwaro katoa | 1 - 8000 ppm | ||
Pūmautanga (hapa ine) | I te ahua whakamatautau ano, kaore he hapa i te 10% mo te tauira hinu kotahi.(te kukū waenga) | ||
akomanga IP | IP66 |
Te teitei | ≤3000m |
Te pāmahana ambient | -10℃~+45℃(roto);-40℃~+70℃(waho) |
Max.rerekētanga pāmahana ia rā | 25℃ |
Max.haumākū whanaunga | 95% (te toharite ia ra);90% (tauwaenga o ia marama) |
Te pehanga hau | 86kPa~106kPa |
Te kaha anti-shock | Te whakatere whakapae 0.30g;whakaterenga poutū 0.15g |
Te taiao whakaurunga | Te whakaurunga o roto.Ko te ruma kia rite ki te hau-a-rangi, kaore he parepare, kaore he mehua anti-static. |
Whakatauhia te hiko hiko (AC) | 220V/100V, hapa whakaaetia ± 20% (harmonics), tapeke ngaohiko reiti distortion ≤8%. |
Whakatauhia te hiko hiko (DC) | 220V/110V, awhe rerekee whakaaetia ±20%. |
Ngaohiko AC Whakatauria | 57.7V / 100V / 220V, ko te kaha o te taumaha he 1.2times o te ngaohiko whakatau, te taunga teitei ≥2. |
Kua whakatauhia te AC o naianei | 1A/5A, ko te kaha taumaha he 1.2 nga wa o naianei kua whakatauhia, kei te mahi tonu, te taunga teitei ≥3. |
auau kua tohua | 50Hz, hapa whakaaetia -5%~+5%. |
Tuku hiko
Ko te tuku hiko o te punaha tirotiro i nga ahuatanga o te teihana kia noho haumaru, kia pono, me te taputapu paparanga mana o te teihana me whakakahahia e te 220VAC Kore Tuturu Mana (UPS).Ko ia wae aroturuki i roto i te paparanga tukanga e whakakahangia ana e te punaha 220V AC.
Te whakamarumaru uira, te papa whenua, te aukati i te pokanoa
Ko te punaha aro turuki i nga ahuatanga o te teihana me whai tikanga whakamarumaru ki te ngaohiko nui.
Karekau he matiti whenua motuhake mo te punaha aro turuki ahuatanga.E ai ki te maataapono o te "one-point grounding", ka hono te waea whenua ki tetahi waahi o te matiti whenua matua o te teihana.
Ka whakauruhia te taputapu whakamarumaru ngaohiko ki runga i te mana hiko 220V AC, te raina korero me te pito matua o te kupenga whenua, me nga tawhā taputapu whakamarumaru kia rite ki te taurangi mahi whakamaarama o nga taputapu.
Ko te tahuhu, te rūnanga me te paparanga whakamarumaru taura o te punaha aro turuki i nga ahuatanga kia tika te whakatuu.Ko te hononga i waenga i nga papa o te tukanga o te punaha aroturuki ahua, te hononga i waenga i te paparanga tukanga me te paparanga mana teihana, me te hononga i waenga i nga tauranga korero o nga taputapu ka wehea.
Ka whakauruhia te taputapu ki roto i tetahi ruma kaore he parenga hiko.Ko te taputapu ake me tutuki nga whakaritenga o te pokanoa mara anti-electromagnetic me te awe hiko.Mena he nui te hiko o te uira, te mahi overvoltage me te hapa poto o nga taputapu tuatahi, kaua e mahi kino nga taputapu, me tutuki nga taputapu katoa ki nga whakaritenga aukati-ahuru e whai ake nei:
1) Mo te whakaheke hiko, ka rite ki te GB / T 17626-4-2 akomanga 4.
2) Mo te mara electromagnetic radiation, ka rite ki te akomanga GB / T 17626-4-3 3.
3) Mo te tere tere, he rite ki te GB/T 17626-4-4 akomanga 4.
4) Mo te ngangau, he rite ki te GB/T 17626-4-5 akomanga 3.
5) Mo te whakahaerenga o te whakauru hiko, ka rite ki te GB / T 17626-4-6 akomanga 3.
6) Mo te waahi hiko hiko, he rite ki te GB / T 17626-4-8 akomanga 4.
7) Mo te papa hiko hiko, he rite ki te GB / T 17626-4-9 akomanga 5.
8) Mo te papa autō oscillating kua whakataka, e rite ana ki te akomanga 5 GB/T 17626-4-10.
9) Mo te ngaru oscillating, he rite ki te GB / T 17626-4-12 akomanga 2 (tauranga tohu).
Kao. | Ingoa Taputapu | Whakatakotoranga | Qty | Korero |
1 | Transformer Oil Gas Pūnaha aroturuki ipurangi | 535*600*1100 | 1 | |
2 | Flange | I runga i te tauranga o te whakawhiti | 2 | |
3 | ngongo kowiri tira | Φ6*30M | 1 | |
4 | muka whatu | Aratau-maha 4-matua, 200M | 1 | |
5 | Pouaka kāpeka | 2 | ||
6 | Kaipekepeke | SC-SC | 2 | |
7 | Kaitahuri muka | aratau maha | 1 | |
8 | taura Itarangi | 0.5M | 2 | |
9 | tīwiri | M12*1.25M, Φ6 | 2 | |
10 | tīwiri roha | M10*100 | 4 | |
11 | Kī rūnanga | 2pcs | 1 | |
12 | Kāri taura | 4pcs+he maha nga here taura nylon | 1 | |
13 | ngongo kowiri tira | Φ3*2M | 1 | |
14 | Paipa Waihanga me etahi atu waahanga | Pupa whakamahana Φ6*2M 4pcs, Au ripene 50*25M 1roll, kowiri tira 8*32 2pcs | 1 |